Warning: Use of undefined constant output - assumed 'output' (this will throw an Error in a future version of PHP) in /homepages/38/d300852396/htdocs/NLS-Datasu-WP/wp-content/themes/passion/functions/theme-shortcodes.php on line 276
Warning: Use of undefined constant output - assumed 'output' (this will throw an Error in a future version of PHP) in /homepages/38/d300852396/htdocs/NLS-Datasu-WP/wp-content/themes/passion/functions/theme-shortcodes.php on line 276
Warning: Use of undefined constant output - assumed 'output' (this will throw an Error in a future version of PHP) in /homepages/38/d300852396/htdocs/NLS-Datasu-WP/wp-content/themes/passion/functions/theme-shortcodes.php on line 276
Warning: Use of undefined constant output - assumed 'output' (this will throw an Error in a future version of PHP) in /homepages/38/d300852396/htdocs/NLS-Datasu-WP/wp-content/themes/passion/functions/theme-shortcodes.php on line 276
Warning: Use of undefined constant output - assumed 'output' (this will throw an Error in a future version of PHP) in /homepages/38/d300852396/htdocs/NLS-Datasu-WP/wp-content/themes/passion/functions/theme-shortcodes.php on line 276
Warning: Use of undefined constant output - assumed 'output' (this will throw an Error in a future version of PHP) in /homepages/38/d300852396/htdocs/NLS-Datasu-WP/wp-content/themes/passion/functions/theme-shortcodes.php on line 276
Fiber Optic and copper cabling systems for industrial and commercial buildings (Cabling systems)
Fiber Optic cabling systems
Connection systems:
SC Duplex, LC-Duplex, MPO, E2000, MU-Duplex, MTP : PC und APC-Version, MT-RJ, ST
Fiber types:
OM1 62,5/125μ, OM2 50/125μ, OM3 50/125μ, OM3e 50/125μ, OS2 9/125μ
Fiber Optic Cable types:
Outdoor cable, Universal cable
Form of delivery:
Pre-assembled on one or both sides with a distribution head including a screwed-on feeder tube as feeding aid and protection of the connectors. Delivery on bobbin or in box. 100 % tested, attenuation measurement report included.
Fields of application:
Secondary and Tertiary Backbone cabling in compliance with ISO/IEC 11801 resp. EN 50173-1.
Main Distribution (MD), Horizontal Distribution (HD), Zone Distribution (ZD) and Equipment Distribution (ED) Areas in Data Centers, Storage Area Networks (SAN) and Server Farms in compliance with ISO/IEC 24764 bzw. EN 50173-5.
Connection systems:
MPO(PIN) - LC Duplex, MPO(PIN) - MT-RJ, MPO - SC-Duplex
Fiber types:
OM1 62,5/125μ, OM2 50/125μ, OM3 50/125μ, OS2 9/125μ
100% tested, attenuation measurement report included.
Field of application:
Connection to the hardware with the MPO-connector and factor assembled MPO Trunk cables according to ISO/IEC 24764 and EN 50173-5.
Fiber type:
OM1 62,5/125μ, OM2 50/125μ, OM3 50/125μ, OS2 9/125μ
Fiber Optic Cable types:
- Outdoor cable: central tube and stranded design with rodent protection
- Universal cable: central tube and stranded design with and without rodent protection
- Break-out Cable
- Duplex Indoor cable Mini-Zip, Figure 0, Figure 8
Main Distribution (MD), Horizontal Distribution (HD), Zone Distribution (ZD) and Equipment Distribution (ED) Areas in Data Centers, Storage Area Networks (SAN) und Server Farms in compliance with ISO/IEC 24764 resp. EN 50173-5.
Connection systems:
SC Duplex, LC-Duplex, E2000, MU-Duplex, MT-RJ, ST, MTP
Fiber types:
OM1 62,5/125μ, OM2 50/125μ, OM3 50/125μ, OS2 9/125μ
Versions:
Fixed installation, telescopic
Form of delivery:
The panels and the couplers are factory assembled. Non used outlets of the frontplates are covered with blind tapes.
Field of application:
Installation in 19" distríbution frames in accordance with ISO/IEC 11801, ISO/IEC 24702 and EN 50173-Series.
For the installation and the application of factory assembled Trunk cables and Break-out Cables.
Connection systems:
SC Duplex, LC-Duplex, E2000, MU-Duplex, MT-RJ, ST
Fiber types:
OM1 62,5/125μ, OM2 50/125μ, OM3 50/125μ, OS2 9/125μ
Versions:
Fixed installation, Telescopic
Form of delivery:
The panels, couplers and splicing cassettes with accessory are factory-assembled and the pigtails pre-inserted. Unused outlets of the front plates are covered with blind tapes.
Field of application:
Installation in 19'' distribution frames in compliance with ISO/IEC 11801, ISO/IEC 24702 and EN 50173-Series.
For the attachment of fiber optic outdoor and indoor cables and for the splicing of pre-inserted pigtails.
Connection systems:
SC, LC, E2000, MU, MT-RJ, ST
Fiber types:
OM1 62,5/125μ, OM2 50/125μ, OM3 50/125μ, OM3e 50/125µ, OS2 9/125μ
Fiber Optic cord types:
Zipcord, Mini-Zip, Figure 0, Figure 8
Form of delivery:
Hybrids available.
100 % tested, measurement report included.
State of the art Copper cabling systems
- Copper trunk cables Classes EA/F/FA
- Copper data cables Category 7
- Copper connection technology Categories 6a/7
- Copper patchcords Categories6a/7
Intelligent patching systems (managementable)
Distribution-Rack Systems – „Cold Corridor“
- "Cold Corridor" system solution
- customized rack solutions
RZ-Equipment
Switching and router technology (e.g. Enterasys)
Analysis, Consulting, Planning and Installation
- Consulting and planning of all active components
- Installation und configuration of all active components
- Documentation of the logical network / CAD-Visio
- Maintenance and service